INT 1A - TIME - GET REAL-TIME CLOCK TIME (AT,XT286,PS)
AH = 02h
Return: CF clear if successful
CH = hour (BCD)
CL = minutes (BCD)
DH = seconds (BCD)
DL = daylight savings flag (00h standard time, 01h daylight time)
CF set on error (i.e. clock not running or in middle of update)

See also: 1A00