INT 17 - Alloy MW386 v2+ - GET/SET SPOOL FLAGS
AH = A7h
AL = spool flags
bit 0: banner page enabled (see AH=A4h)
1: form feed enabled (see AH=A6h)
2-6: reserved (0)
7: set flags if 1, get flags if 0
BX = logical device number
00h-03h = LPT1-LPT4
04h-07h = COM1-COM4
Return: AL = status (see AH=81h)
Note:   the documentation does not state which register contains the result of
a GET
SeeAlso: AH=A6h

See also: 17A4

17A7 - Alloy MW386 v2+ - GET/SET SPOOL FLAGS