INT 17 - Alloy NTNX, MW386 - SET DATA DRIVEN PRINT BREAK
AH = 97h
AL = mode
00h NTNX compatibility
02h MW386 v2+
BX = logical device number
00h-03h = LPT1-LPT4
04h-07h = COM1-COM4
CH,CL,DH = three character break sequence
DL = subfunction
00h set break string
else reset break
Return: AL = status (see AH=81h)
Notes:  mode 00h affects only logical LPT1
when the break string is encountered, the spool file will be closed and
queued for printing automatically
the break string is not permanently saved, and will be reset each time
MW386 or the user is rebooted

See also: 179B

1797 - Alloy NTNX, MW386 - SET DATA DRIVEN PRINT BREAK