INT 15 - EISA SYSTEM ROM - READ FUNCTION CONFIGURATION INFORMATION
AX = D801h
CH = function number to read
CL = slot number (including embedded and virtual)
DS:SI -> 320-byte buffer for standard configuration data block
Return: CF clear if successful
AH = 00h
DS:SI buffer filled
CF set on error
AH = error code
80h invalid slot number
81h invalid function number
82h EISA CMOS corrupt
83h empty slot
86h invalid BIOS-FW function call
87h invalid system configuration
BX destroyed
Note:   call with AL=81h if using 32-bit CS addressing mode instead of 16-bit


15D801 - EISA SYSTEM ROM - READ FUNCTION CONFIGURATION INFORMATION