INT 10 - SOLLEX SuperVGA - DISPLAY OUTPUT CONTROL - GET DISPLAY OUTPUT
AX = 7F02h
BL = 01h
Return: AL != 7Fh if not supported
AL = 7Fh if supported
AH = status
00h successful
BX = display output setting (see AX=7F02h/BL=00h)
CX = displays attached
bit 0: PS/2 display on analog output
bit 1: multi-frequency monitor on analog output
bit 2: LCD panel attached
bit 3: plasma/electroluminescent panel attached
bit 4: multi-frequency monitor on digital output
bit 5: Enhanced Color Display attached to digital outpt
bit 6: alternate display
bits 15-7: reserved
01h failed
SeeAlso: AX=7F02h/BL=00h

See also: 107F00

107F02BL01 - SOLLEX SuperVGA - DISPLAY OUTPUT CONTROL - GET DISPLAY OUTPUT